Clear Comfort Water, Inc. · UV and Supplemental Treatment · Advanced oxidation (non-UV)
Clear Comfort hydroxyl-based AOP systems
Hydroxyl-radical advanced oxidation alongside chlorine — not UV, not ozone
Overview
Clear Comfort's AOP is a distinct technology from ultraviolet or ozone supplemental treatment. The manufacturer states its patented process "directly creates hydroxyl radicals in the water without multiple systems." It is positioned as a secondary or supplemental treatment that runs alongside chlorine, not a chlorine replacement.
Three models cover a range of recirculation flows: CCW300A for entry commercial pools and splash pads, CCW300 for medium commercial pools and splash pads, and CCW500 for large commercial pools and water parks. Clear Comfort sizes systems by recirculation flow in gallons per minute (GPM), not pool gallonage. The manufacturer names hotels, universities, water parks, spas, YMCAs, recreation centers, and professional sports hydrotherapy pools among the facility types it serves.
FreyTech represents Clear Comfort AOP systems for New York facilities; availability and lead time are confirmed when you contact FreyTech.
Is this a fit for your facility?
Usually a fit when
- Facilities adding a secondary disinfection barrier alongside an existing chlorine program
- Pools and splash pads within a model's published recirculation-flow range
- Hotels, universities, water parks, spas, YMCAs, recreation centers, and professional sports hydrotherapy pools, per the manufacturer
Look elsewhere when
- Facilities expecting AOP to replace chlorine rather than supplement it
- Sites where the unit cannot be located within 15 ft of the Venturi injection site
- Recirculation flows above the CCW500's published 2,000 GPM maximum
Ideal facilities and conditions: Entry-level commercial pools and splash pads (CCW300A); Medium commercial pools and splash pads (CCW300); Large commercial pools and water parks (CCW500).
Problems it addresses
Key capabilities and benefits
Capabilities
- Direct hydroxyl-radical injection (patented AOP) — not UV, not ozone
- Sized by recirculation flow (GPM), not pool gallonage
- Runs only when the recirculation pump runs, per the manufacturer
- Annual cartridge replacement; manufacturer states no other maintenance is required
Operational and buyer benefits
- A secondary disinfection barrier alongside chlorine
- Simple, scheduled annual maintenance
- Sizing keyed to the facility's actual recirculation flow rather than pool volume
Available models and configurations
Technical specifications
| Technology | Patented hydroxyl-based Advanced Oxidation Process (AOP): direct hydroxyl-radical injection. Not UV; not ozone.Source: clearcomfort.com/hydroxyl-advanced-oxidation-aop-technology/ |
|---|---|
| Positioning | Secondary/supplemental treatment used alongside chlorine; not a chlorine replacementSource: clearcomfort.com/commercial/ |
| Certifications / listings | "ANSI/NSF 50 | UL 1563 | EPA Section 7 FIFRA Act" per the manufacturer; UL File No. E482558; EPA Establishment No. 91122-CO-3Source: clearcomfort.com/support/commercial-key-features/ |
| Installation conditions | Ambient 40–90 °F; unit must be located within 15 ft of the Venturi injection site; CCW300/CCW300A are pole- or wall-mountable, CCW500 is floor-standing; runs only when the recirculation pump runsSource: clearcomfort.com/support/commercial-key-features/ |
| Maintenance | "The Cartridge must be replaced annually. No other maintenance is required."Source: clearcomfort.com/commercial-cartridge-exchange/ |
| Warranty (manufacturer) | 5-year system warrantySource: clearcomfort.com/support/commercial-key-features/ |
Specifications are summarized from manufacturer literature and depend on configuration. Confirm current values with FreyTech before design.
Installation requirements and retrofit considerations
Prerequisites
- Venturi injection point within 15 ft of the unit
- Ambient temperature 40–90 °F at the install location
- Recirculation pump interlock so the unit runs only when the pump runs
- Pole, wall, or floor mounting location confirmed per model
Retrofit and replacement notes
- Commonly added alongside an existing chlorine program during a modernization, rather than replacing it
- Confirm recirculation flow (GPM), not pool gallonage, against the model's published range before sizing
Integration with other equipment
- Chlorine sanitizer programPositioned by the manufacturer as a secondary treatment that runs alongside chlorine, not a replacement.Manufacturer-documented
- Recirculation pumpThe unit runs only when the recirculation pump runs, per the manufacturer.Manufacturer-documented
FreyTech's role: design, installation, commissioning, training, support
Project services
- Evaluating whether supplemental AOP treatment fits the facility's secondary-disinfection goals
- Coordinating sizing by recirculation flow (GPM) with the engineer
- Supply and installation coordination
Ongoing service and support
- Annual cartridge replacement
- Warranty coordination through FreyTech
Brochures, manuals, warranties and specifications
- Product pageClear Comfort hydroxyl AOP technology (opens manufacturer site)Web · Manufacturer-hosted
- Product pageClear Comfort commercial AOP overview (opens manufacturer site)Web · Manufacturer-hosted
- Product pageCCW300A / CCW300 AOP system (opens manufacturer site)Web · Manufacturer-hosted
- Product pageCCW500 AOP system (opens manufacturer site)Web · Manufacturer-hosted
- Engineering resourceCommercial key features (certifications and install conditions) (opens manufacturer site)Web · Manufacturer-hosted
- Owner's manualCommercial cartridge exchange (maintenance) (opens manufacturer site)Web · Manufacturer-hosted
- Specification sheetNSF/ANSI 50 certificate (opens manufacturer site)PDF · Manufacturer-hosted
All resources for Clear Comfort hydroxyl-based AOP systems · Request documents
Clear Comfort hydroxyl-based AOP systems: frequently asked questions
Is this a UV system?
No. Clear Comfort states its patented AOP directly creates hydroxyl radicals in the water without multiple systems; the company describes it as distinct from UV and from ozone.
Does it replace chlorine?
No. Clear Comfort positions AOP as a secondary or supplemental treatment that runs alongside chlorine.
How is a system sized?
By recirculation flow in GPM, not pool gallonage: CCW300A up to 350 GPM, CCW300 up to 700 GPM, CCW500 up to 2,000 GPM.
What maintenance does it need?
Clear Comfort states the cartridge must be replaced annually and that no other maintenance is required.
Next step
Is Clear Comfort hydroxyl-based AOP systems right for your facility?
Send us your pool volumes, current equipment, and what is not working. A specialist will review fit honestly and recommend next steps.