Serving commercial aquatic facilities across New York State.

Talk With Angelo

Clear Comfort Water, Inc. · UV and Supplemental Treatment · Advanced oxidation (non-UV)

Clear Comfort hydroxyl-based AOP systems

Hydroxyl-radical advanced oxidation alongside chlorine — not UV, not ozone

← Back to all productsAvailable through FreyTechFacts verified against manufacturer literature 2026-09-26.

Overview

Clear Comfort's AOP is a distinct technology from ultraviolet or ozone supplemental treatment. The manufacturer states its patented process "directly creates hydroxyl radicals in the water without multiple systems." It is positioned as a secondary or supplemental treatment that runs alongside chlorine, not a chlorine replacement.

Three models cover a range of recirculation flows: CCW300A for entry commercial pools and splash pads, CCW300 for medium commercial pools and splash pads, and CCW500 for large commercial pools and water parks. Clear Comfort sizes systems by recirculation flow in gallons per minute (GPM), not pool gallonage. The manufacturer names hotels, universities, water parks, spas, YMCAs, recreation centers, and professional sports hydrotherapy pools among the facility types it serves.

FreyTech represents Clear Comfort AOP systems for New York facilities; availability and lead time are confirmed when you contact FreyTech.

Is this a fit for your facility?

Usually a fit when

  • Facilities adding a secondary disinfection barrier alongside an existing chlorine program
  • Pools and splash pads within a model's published recirculation-flow range
  • Hotels, universities, water parks, spas, YMCAs, recreation centers, and professional sports hydrotherapy pools, per the manufacturer

Look elsewhere when

  • Facilities expecting AOP to replace chlorine rather than supplement it
  • Sites where the unit cannot be located within 15 ft of the Venturi injection site
  • Recirculation flows above the CCW500's published 2,000 GPM maximum

Ideal facilities and conditions: Entry-level commercial pools and splash pads (CCW300A); Medium commercial pools and splash pads (CCW300); Large commercial pools and water parks (CCW500).

Problems it addresses

Key capabilities and benefits

Capabilities

  • Direct hydroxyl-radical injection (patented AOP) — not UV, not ozone
  • Sized by recirculation flow (GPM), not pool gallonage
  • Runs only when the recirculation pump runs, per the manufacturer
  • Annual cartridge replacement; manufacturer states no other maintenance is required

Operational and buyer benefits

  • A secondary disinfection barrier alongside chlorine
  • Simple, scheduled annual maintenance
  • Sizing keyed to the facility's actual recirculation flow rather than pool volume

Available models and configurations

CCW300AEntry commercial pools and splash pads; 350 GPM maximum.
CCW300Medium commercial pools and splash pads; 700 GPM maximum.
CCW500Large commercial pools and water parks; 2,000 GPM maximum.

Technical specifications

TechnologyPatented hydroxyl-based Advanced Oxidation Process (AOP): direct hydroxyl-radical injection. Not UV; not ozone.Source: clearcomfort.com/hydroxyl-advanced-oxidation-aop-technology/
PositioningSecondary/supplemental treatment used alongside chlorine; not a chlorine replacementSource: clearcomfort.com/commercial/
Certifications / listings"ANSI/NSF 50 | UL 1563 | EPA Section 7 FIFRA Act" per the manufacturer; UL File No. E482558; EPA Establishment No. 91122-CO-3Source: clearcomfort.com/support/commercial-key-features/
Installation conditionsAmbient 40–90 °F; unit must be located within 15 ft of the Venturi injection site; CCW300/CCW300A are pole- or wall-mountable, CCW500 is floor-standing; runs only when the recirculation pump runsSource: clearcomfort.com/support/commercial-key-features/
Maintenance"The Cartridge must be replaced annually. No other maintenance is required."Source: clearcomfort.com/commercial-cartridge-exchange/
Warranty (manufacturer)5-year system warrantySource: clearcomfort.com/support/commercial-key-features/

Specifications are summarized from manufacturer literature and depend on configuration. Confirm current values with FreyTech before design.

Installation requirements and retrofit considerations

Prerequisites

  • Venturi injection point within 15 ft of the unit
  • Ambient temperature 40–90 °F at the install location
  • Recirculation pump interlock so the unit runs only when the pump runs
  • Pole, wall, or floor mounting location confirmed per model

Retrofit and replacement notes

  • Commonly added alongside an existing chlorine program during a modernization, rather than replacing it
  • Confirm recirculation flow (GPM), not pool gallonage, against the model's published range before sizing

Integration with other equipment

  • Chlorine sanitizer programPositioned by the manufacturer as a secondary treatment that runs alongside chlorine, not a replacement.
    Manufacturer-documented
  • Recirculation pumpThe unit runs only when the recirculation pump runs, per the manufacturer.
    Manufacturer-documented

FreyTech's role: design, installation, commissioning, training, support

Project services

  • Evaluating whether supplemental AOP treatment fits the facility's secondary-disinfection goals
  • Coordinating sizing by recirculation flow (GPM) with the engineer
  • Supply and installation coordination

Ongoing service and support

  • Annual cartridge replacement
  • Warranty coordination through FreyTech

Brochures, manuals, warranties and specifications

All resources for Clear Comfort hydroxyl-based AOP systems · Request documents

Clear Comfort hydroxyl-based AOP systems: frequently asked questions

Is this a UV system?

No. Clear Comfort states its patented AOP directly creates hydroxyl radicals in the water without multiple systems; the company describes it as distinct from UV and from ozone.

Does it replace chlorine?

No. Clear Comfort positions AOP as a secondary or supplemental treatment that runs alongside chlorine.

How is a system sized?

By recirculation flow in GPM, not pool gallonage: CCW300A up to 350 GPM, CCW300 up to 700 GPM, CCW500 up to 2,000 GPM.

What maintenance does it need?

Clear Comfort states the cartridge must be replaced annually and that no other maintenance is required.

Next step

Is Clear Comfort hydroxyl-based AOP systems right for your facility?

Send us your pool volumes, current equipment, and what is not working. A specialist will review fit honestly and recommend next steps.

Serving commercial aquatic facilities across New York State.