BECSys ChemLock

An independent interlock that stops chemical feed whenever the circulation pump is not running

← Back to all productsAvailable through FreyTechFacts verified against manufacturer literature 2026-09-15.

Overview

ChemLock provides a second, independent mechanism for locking out chemical feed when the circulation pump is not running. It complements the controller's own no-flow lockout so that a single failure cannot allow chemical to feed into a stagnant line. BECS lists it as UL 508A approved.

Is this a fit for your facility?

Usually a fit when

  • Facilities that want an independent feed interlock in addition to the controller
  • Renovations where the engineer specifies redundant chemical-feed safety

Look elsewhere when

  • Sites without a controllable feed system to interlock

Ideal facilities and conditions: Any commercial pool with pumped or erosion chemical feed.

Problems it addresses

Key capabilities and benefits

Capabilities

  • Independent lockout of chemical feeds when the circulation pump is off
  • UL 508A approved panel
  • Works alongside BECSys controllers

Operational and buyer benefits

  • Defense in depth for the requirement that feeders deactivate without recirculation flow (10 NYCRR 6-1.29 item 11.7)
  • Clear, inspectable safety function for engineers and health departments

Technical specifications

FunctionIndependent chemical-feed lockout tied to circulation pump statusSource: SLS-6152-A
ApprovalUL 508A approvedSource: SLS-6152-A

Specifications are summarized from manufacturer literature and depend on configuration. Confirm current values with FreyTech before design.

Installation requirements and retrofit considerations

Prerequisites

  • Circulation pump status signal
  • Controllable feed equipment

Retrofit and replacement notes

  • Typically added during a controller replacement or feed-system upgrade

Integration with other equipment

  • BECSys3/5/7Designed to work with BECS controllers.
    Manufacturer-documented
  • Pulsar feeders and metering pumpsInterlocks the feed power/solenoid circuit.
    Commonly considered together · requires technical confirmation

Often specified with

  • BECSys5Expandable water-chemistry controller: pH, ORP, and temperature standard; free-chlorine PPM, alkalinity, flow, pressures, inventory, VFD, UV, and heater control optional. Ethernet, alarms, and BECSys Live included.
    Documented pairing
  • Pulsar PrecisionPatented high-capacity erosion feeder for calcium hypochlorite briquettes; manufacturer-rated for 500,000 to 1,000,000+ gallon pools; up to 189 lb/day available chlorine.
    Commonly considered together

“Commonly considered together” means the pairing is typical in practice; technical compatibility is confirmed for each project.

FreyTech's role: design, installation, commissioning, training, support

Project services

  • Specification support
  • Installation and interlock testing at commissioning

Ongoing service and support

  • Annual interlock verification within service agreements

Brochures, manuals, warranties and specifications

All resources for BECSys ChemLock · Request documents

BECSys ChemLock: frequently asked questions

Doesn't the controller already stop feed on no flow?

Yes. ChemLock adds an independent path so the safety function does not depend on a single device.

Explore compatible chemical-delivery approaches

  1. Measure

    BECSys5

  2. Control

    BECSys5

  3. Feed

    Pulsar Precision

  4. Monitor

    BECSys Live

  5. Support

    FreyTech

Next step

Is BECSys ChemLock right for your facility?

Send us your pool volumes, current equipment, and what is not working. A specialist will review fit honestly and recommend next steps.

Serving commercial aquatic facilities across New York State.