Overview
BECSys5 is BECS Technology's expandable controller for commercial pools. Out of the box it measures pH, ORP, and temperature through a machined flow cell with a flow switch, drives up to four chemical feeds on solid-state relays, logs a year of one-minute readings, and sends email and text alarms over its built-in Gigabit Ethernet connection.
Optional sensors and modules extend it to true free-chlorine PPM control, total alkalinity, conductivity, turbidity, flow, pressures, tank levels, and chemical inventory, plus control of VFD recirculation pumps, UV, ozone, heaters, and makeup water and interfaces to building-management systems. Remote access through BECSys Live is included at no additional fee.
Is this a fit for your facility?
Usually a fit when
Institutional pools that need alarms, records, and remote visibility
Facilities replacing a discontinued or unsupported controller
Multi-pool campuses standardizing on one platform
Renovations integrating pumps, VFDs, UV, or heaters
Look elsewhere when
A single small pool that only needs pH/ORP with no communications (see BECSys3)
Mechanical rooms that need automatic filter backwash from the controller (see BECSys7)
Ideal facilities and conditions: Competition and lap pools; Therapy pools and spas; Municipal indoor and outdoor pools; Multi-pool YMCAs and campuses.
pH, ORP, and temperature sensors, flow switch, and machined flow cell standard
Four solid-state relays, expandable to 19 with SRX/MRX modules
Gigabit Ethernet; email and text alarm notification
One year of 1-minute readings and one year of events in non-volatile memory
No-flow feed lockout, failsafe overfeed timers to 18 hours, pH-alarm sanitizer lockout, emergency off
Three-level access codes
NEMA 4X (IP66) enclosure; 115/230 VAC
Operational and buyer benefits
Fewer blind spots: dashboards, alarms, and trends reach the people responsible
More consistent water through continuous control rather than periodic correction
Records that can be reviewed with the health department alongside the required daily log
Continuity through staff turnover: documented setpoints and logged changes
One platform that grows as the mechanical room is modernized
Available models and configurations
BECSys5 standardpH/ORP/temperature control with Ethernet, alarms, logging, and BECSys Live.
With free/total chlorine PPMDirect PPM monitoring and control with optional sensors; combined-chlorine tracking.
With BECSys Alkalinity MeterTotal alkalinity monitoring and control.
With flow/pressure/VFD optionSystem flow, pressures, TDH monitoring and patented VFD recirculation-pump control via 4–20 mA output.
With BMS interfaceModbus TCP/IP, BACnet, Metasys N2, or LonWorks.
Technical specifications
Standard measurements
pH, ORP, temperature; flow switchSource: TDS-4262
Optional measurements
Free/total/combined chlorine (PPM), total alkalinity, conductivity/TDS, turbidity, system flow, pressures, vacuum, TDH, tank levels, chemical inventorySource: TDS-4262
Outputs
4 solid-state relays standard; up to 19 with expansion modules; optional 4–20 mA outputSource: TDS-4262
BECSys Live (no fee), BECSys for Windows, BECSys Now! appSource: SLS-4333-H
Data logging
365 days of 1-minute readings; 365 days of events; NAND flash, no batterySource: TDS-4262
Safety
No-flow lockout with flow-restored delay; failsafe overfeed timers (1-minute steps to 18 h); pH-alarm sanitizer lockout; emergency offSource: TDS-4262
Enclosure / power
Glass-reinforced polycarbonate, NEMA 4X (IP66); 115/230 VAC 50/60 HzSource: TDS-4262
Listings
NSF Certified and Listed to NSF/ANSI 50; ETL Listed to ANSI/UL 61010-1Source: TDS-4262
Warranty (manufacturer)
5 years electronics; 2 years pH/ORP/temperature sensors; 1 year optional sensors and flow cellSource: SLS-4333-H / TDS-4262
Specifications are summarized from manufacturer literature and depend on configuration. Confirm current values with FreyTech before design.
Installation requirements and retrofit considerations
Prerequisites
A sound sample loop: adequate sample flow, strainer, and a location for the flow cell
Feed equipment with controllable outputs (solenoids, metering pumps, feeder valves)
115 or 230 VAC circuit
Network drop or Wi-Fi option for alarms and BECSys Live
Chemical storage and interlock wiring reviewed for New York requirements
Retrofit and replacement notes
Most replacements reuse the existing sample line and feed equipment with a new flow cell and probes
Typical cutover is one to two days on site plus stabilization and training
Adding sensors, relays, VFD, or BMS interfaces extends scope and may involve the engineer and permit-issuing official (6-1.8)
Integration with other equipment
Pulsar Precision and Precision 30 feedersFeeder solenoid driven by the controller's chlorine-demand output.
Manufacturer-documented
Metering pumps and CO2 pH controlStandard relay outputs; CO2 systems per BECS literature.
Manufacturer-documented
SpinTouch and Lumiso digital test kitsAutomatic upload of readings.
Manufacturer-documented
VFDs, UV, ozone, heaters, autofillConfiguration-dependent optional control functions.
Manufacturer-documented
Building management systemsOptional Modbus TCP/IP, BACnet, Metasys N2, LonWorks interfaces.
Manufacturer-documented
BECSys ChemLockIndependent UL 508A chemical-feed interlock.
Manufacturer-documented
Often specified with
Pulsar PrecisionPatented high-capacity erosion feeder for calcium hypochlorite briquettes; manufacturer-rated for 500,000 to 1,000,000+ gallon pools; up to 189 lb/day available chlorine.
Documented pairing
Pulsar Precision 30Flow-based erosion feeder with a 30 lb hopper; 2–36 lb/day available chlorine; manufacturer-recommended pool size 10,000–300,000 gallons.
Documented pairing
BECSys ChemLockUL 508A-approved interlock panel that locks out chemical feeds independently of the controller when circulation stops.
Documented pairing
Taylor Technologies Test KitsCommercial 2000-series DPD and FAS-DPD test kits and reagents from Taylor Technologies (Fluidra); 18 Taylor kits are certified to NSF/ANSI/CAN 50 per the manufacturer.
Commonly considered together
“Commonly considered together” means the pairing is typical in practice; technical compatibility is confirmed for each project.
FreyTech's role: design, installation, commissioning, training, support
Project services
Assessment of the sample loop, feed equipment, network, and storage
Configuration and submittals against your point list
Installation by FreyTech technicians
Commissioning: calibration against manual tests, setpoints, alarm limits, failsafe and no-flow tests, alarm delivery test, settings record
Operator and supervisor training with written procedures
Ongoing service and support
Phone support and remote diagnostics through BECSys Live
Preventive maintenance visits for calibration and probe replacement
BECSys5 Technical Data Sheet (TDS-4262)PDF · Available on request · Official copy available to FreyTech through the BECS distributor portal; provided on request pending permission to host.
Owner's manual
BECSys5 Operator's ManualPDF · Available on request · Provided to customers with the system; not publicly hosted by BECS.
Installation manual
BECSys5 Installation & Technical ManualPDF · Available on request · Provided to installers and engineers on request.
Entry-level BECS controller with a two-line display, pH/ORP control, optional free-chlorine sensor, and an optional Communications module for BECSys Live.